Sample Preparation
Typically, titanium and zirconium samples are chemically etched to remove surface contamination when oxygen and nitrogen are determined. However, etching can introduce hydrogen into the sample.
ASTM method E 1409 "Determination of Oxygen and Nitrogen in Titanium and Titanium Alloys by the Inert
Gas Fusion Technique", as updated in 1996, permits either etching or abrading (filing) of the test specimen.
ASTM E 1447 "Determination of Hydrogen in Titanium and Titanium Alloys by the Inert Gas Fusion Thermal
Conductivity/Infrared Detection Method" permits surface preparation by abrading (if necessary to remove
contamination). Differences in sample preparation present somewhat of a dilemma regarding simultaneous
determination of O, N, and H in titanium. However, abrading samples with a file to remove surface
contamination will yield accurate O, N, and H results. The ONH836 utilizes a high-power electrode furnace to quickly and efficiently release the target gases from within the sample, which allows for a very rapid simultaneous determination of oxygen, nitrogen, and hydrogen.
高级诊断程序包括全数字化的在线操作手册、维护模拟演示、图片说明等提供快速指导。江苏LECO分析仪多少钱ONH836氧氮氢分析仪
高频燃烧红外检测技分析无机材料中的碳、硫含量。
采用惰性气体保护熔融法,提供各种无机材料、钢铁、有色金属、硬质合金、难熔金属、陶瓷等材料中宽范围的氧氮氢同时分析。
该仪器配置MS Windows®的软件接口,专为触摸屏操作定制。长期的开发研究与客户反馈相结合,这个简单方便的软件使得用户可以快速完整访问仪器控制,分析设置,故障诊断,数据报告, **提高日常分析的效率并节省用户宝贵的时间。 可选的Cornerstone® Mobile软件功能,使得用户可以在手机,便携式电脑及台式电脑上便捷的访问仪器数据,分析曲线图形以及仪器的状态,实现对仪器的遥控。
江苏LECO分析仪多少钱***电极炉头设计,提高脉冲炉热交换效率。
Procedure - Solid Samples:
--Instrument calibration/drift correction.
Place the nickel basket containing the calibration/drift standard into the open port at the top of the loading head.
Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.
Clean the upper and lower electrode manually, or, if applicable, remove the crucible and press the analyze button to clean with the automatic cleaner.
Procedure – Powder/Chip Samples
Instrument calibration/drift correction.
Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open.
Place the Nickel Capsule containing the sample into the open port at the top of the loading head.
Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.
Clean the upper and lower electrode either manually or remove the crucible and press the analyze button to clean with an automatic cleaner if applicable.
力可OHN736&836系列仪器采用惰性熔融法,提供各种无机材料、钢铁、有色金属、硬质合金陶瓷材料中宽范围的氧氮氢同时测定。ONH836仪器通过***采纳客户的反馈意见和创新设计,力可***仪器采用触摸屏技术和在线软件平台,增强了仪器的可操作性,降低了分析成本,节省实验室桌面空间。
用户友好界面的Cornerstone™ 软件
力可**的Cornerstone碳硫分析软件采用触摸屏界面使用户可完整的达到分析控制、方法设定、在线诊断、数据报告。Cornerstone碳硫分析软件允许用户在单一分析界面中完成日常的所有工作,快速而且简单易用。力可创新的批次和重复样品数据分组功能极大简化了样品结果输出和结果标准偏差的自动计算。减少了繁琐的额外数据处理。
上海禹重给您提供各种氧氮氢分析仪,欢迎来电咨询!新疆美国分析仪采购
Cornerstone氧氮氢分析软件分成4个主要部分:分析、诊断、设定、仪器,界面可快速导航和组织。江苏LECO分析仪多少钱
氧氮氢分析仪的常见故障及解决方法:
氧和氮空白值超过20。这是由于气流小,不能将炉子中的空气驱赶出去。可调节气体流量,调节载气压力在0.2~0.4MPa。接通仪器载气,放一个石墨坩埚在下电极上,打开主电源开关,点击软件上的关炉按钮,关闭炉子并等待10s。调节流量调节器,直到流量计a显示为30L/h,打开炉子。调节调节器直到流量计b显示为50L/h,再次关闭炉子。如果以上设置不稳定,则增加流量至100L/h,反复调节直至仪器稳定。 江苏LECO分析仪多少钱
新漫售后服务部能为用户提供周到及时的保修和技术支持服务。如果因为产品设计或者生产装配质量的原因造成的...
【详情】ISO9001标准涉及了技术法规、标准和合格评定程序。世贸/技术壁垒协定(WTO/TBT)也是WTO...
【详情】在医疗领域,辐射检测至关重要。医院中使用的X光、CT、核磁共振(部分核磁共振使用放射性同位素时会涉及...
【详情】检测点位的选择和布局直接影响检测结果的准确性和代表性。应根据检测目的和辐射源的分布情况,合理确定检测...
【详情】辐射检测人员培训与资质要求:辐射检测人员需经过专业培训并具备相应资质。培训内容包括辐射基础知识、检测...
【详情】环境辐射检测旨在了解环境中天然和人工辐射的水平及其变化情况。天然辐射包括宇宙射线和地球上的天然放射性...
【详情】辐射检测过程中可能会遇到各种突发情况,检测人员需做好应对准备。如果仪器突然出现故障,如显示异常、数据...
【详情】地质勘探中,辐射检测可以提供有价值的信息。一些岩石和矿石中含有天然放射性核素,通过测量岩石和土壤中的...
【详情】不同能量辐射检测比较: 不同能量辐射的检测方法和难度存在差异。低能辐射如α射线,穿透能力弱,检测时需...
【详情】主动式与被动式辐射检测比较: 主动式辐射检测和被动式辐射检测在原理和应用上有明显区别,主动式检测通过...
【详情】核能行业是辐射检测的重点领域。核电站的运行涉及到大量的放射性物质,一旦发生泄漏,将对环境和公众造成严...
【详情】