氧氮氢分析仪的优点

采用惰气熔融技术,同时测定氧、氮和氢元素含量

新设计封闭气路系统,优化气路循环,使氧氮氢测量更准确

可采用更廉价的氩气作为载气

催化炉温度可调,使氧的测量更加准确

气路系统都采用电磁阀控制,新增分段式漏气检测

水冷样品加样端口,有效隔绝杂质气体侵入

仪器配置和氧、氮、氢测量范围可灵活选择

新设计的高灵敏度红外检测池和热导池,有极低的检出限

分析时间短

脉冲炉功率高达8.5kw,温度3000℃

颗粒状样品无需胶囊包裹,使用经济实惠

化学试剂及管路隐藏在门后(可移除)

强大的分析软件(支持数据和应用报告导出、增加评论区及其他更多功能)。

单点和多点校正(线性回归)

可采用自来水、冷却循环水机或交换机冷却

新设计的产品可用于各类生产控制和实验室。


Cornerstone氧氮氧分析软件允许用户在单一分析界面中完成日常的所有工作,快速而且简单易用。山东美国LECO分析仪咨询报价

山东美国LECO分析仪咨询报价,分析仪

Sample Preparation

Typically, titanium and zirconium samples are chemically etched to remove surface contamination when oxygen and nitrogen are determined. However, etching can introduce hydrogen into the sample.

ASTM method E 1409 "Determination of Oxygen and Nitrogen in Titanium and Titanium Alloys by the Inert

Gas Fusion Technique", as updated in 1996, permits either etching or abrading (filing) of the test specimen.

ASTM E 1447 "Determination of Hydrogen in Titanium and Titanium Alloys by the Inert Gas Fusion Thermal

Conductivity/Infrared Detection Method" permits surface preparation by abrading (if necessary to remove

contamination). Differences in sample preparation present somewhat of a dilemma regarding simultaneous

determination of O, N, and H in titanium. However, abrading samples with a file to remove surface

contamination will yield accurate O, N, and H results. The ONH836 utilizes a high-power electrode furnace to quickly and efficiently release the target gases from within the sample, which allows for a very rapid simultaneous determination of oxygen, nitrogen, and hydrogen.

北京LECO分析仪哪家好力可创新的批次和重复样品数据分组功能极大简化了样品结果输出和结果标准偏差的自动计算。

山东美国LECO分析仪咨询报价,分析仪

Sample Preparation


Sampling and sample preparation is an important issue because traditional methods used to obtain samples for oxygen and nitrogen determination are different from those recommended for hydrogen, especially when sampling molten metal. The main difference in steel sampling procedures for oxygen/nitrogen and hydrogen is due to the mobilityof hydrogen. Special precautions must be used when sampling for hydrogen. From molten steel and iron, a sample must be quickly quenched in cold water and chilled in a refrigerant such as liquefied nitrogen or a mixture of acetone and solid carbon dioxide in order to reduce losses of hydrogen from diffusion. Losses of oxygen and nitrogen from diffusion are not a problem. A sample that is taken for hydrogen and

chilled in a refrigerant can also be used for oxygen and nitrogen determination. However, a sample that is typically taken for oxygen and/or nitrogen determination is not suitable for hydrogen determination due to hydrogen loss (diffusion). Surface contamination must be removed by filing or light grinding, using care not to overheat the sample.


Instrument Highlights and Features


Optional Features

Optional boom-mounted touch-screen interface package (M) promotes an ergonomic workspace

Optional Performance Package (P) adds a three-stage carrier gas purification system, and a dual-loop gas dose module

Optional Dual Cooling Package (D) adds an integratedliquid-to-air radiator with dual cooling fans. This DC

option gives the user the choice of liquid-to-liquid cooling, liquid-to-air cooling, or a combination of both

Optional integrated autocleaner (H) automatically cleans the upper electrode and lower electrode tip

Optional 20-sample shuttle loader available



无需人工干预的全自动清扫系统。

山东美国LECO分析仪咨询报价,分析仪

Method Selection


Two methods are described in this application note; either method can be used to analyze iron, steel, nickel-, and cobalt-base alloys. The Precision Method is recommended for general use and will provide the best precision and accuracy throughout the typical O, N, and H concentrations found in this group of metals; approximate cycle time is 3.5 minutes. The Fast Track method can be used where speed of analysis is a critical component; for example, when molten metal is being sampled and results are required in the shortest possible time. This method will produce suitable results for most samples; approximate cycle time is 2.25 minutes. As noted above, sampling and sample preparation are key elements to accurate O, N, and Hdetermination as well. It is up to the user to determine which method best meets their needs.








可选六轴可旋转触摸屏幕,增强了操作的工效和直观性。上海美国分析仪采购

上海禹重给您提供各种氧氮氢分析仪,欢迎来电咨询!山东美国LECO分析仪咨询报价

Sample Preparation


Sampling and sample preparation of refractory metals such as titanium and zirconium is somewhat different from that of steel. Unlike steel samples, hydrogen is not as mobile in this group of materials; therefore, storage in liquid nitrogen or dry ice is not required. However, it is important to keep the sample cool when cutting or sectioning. Sample preparation for oxygen and nitrogen determination has beendifferent from that of hydrogen determination.



山东美国LECO分析仪咨询报价

上海禹重实业有限公司总部位于友东路237号1幢104室,是一家从事仪器科技、医疗科技、检测科技领域内的技术咨询、技术服务,仪器仪表的修理,仪器仪表、实验室设备、机械设备及配件、机电设备及配件、电子产品、化工产品及原料(除危险化学品、监控化学品、烟花爆竹、民用易爆物品、易制毒化学品)、第二类医疗器械的销售,机械设备租赁,电子商务,货物进出口,技术进出口。的公司。禹重科技深耕行业多年,始终以客户的需求为向导,为客户提供***的光谱仪,色谱仪,质谱仪,样品前处理。禹重科技致力于把技术上的创新展现成对用户产品上的贴心,为用户带来良好体验。禹重科技创始人胡景娜,始终关注客户,创新科技,竭诚为客户提供良好的服务。

与分析仪相关的文章
与分析仪相关的问题
与分析仪相关的搜索
信息来源于互联网 本站不为信息真实性负责