Procedure–Powder/ChipSamplesDeterminetheinstrumentblank.PresstheAnalyzebuttonontheinstrumentscreen,thelowerelectrodewillcloseandtheanalysissequencewillstartandendautomatically.Repeatsteps2bthrough2gaminimumofthreetimes.Settheblankfollowingtheprocedureoutlinedintheoperatorsinstructionmanual.Instrumentcalibration/driftcorrection.LoginaminimumofthreeStandardreps.Weighapproximately***gramsofacalibration/driftstandardintoa***NickelCapsule;enterthemassandstandardidentificationintoappropriaterepfi elds.Ifapplicable,placethenickelcapsuleintheappropriateautoloaderposition.Note:LECOReferenceMateria***onotrequirepreparation.Seepreparationstatementonthereferencematerialcertificate.SolidStandardsmaybeusedtocalibratewhenchiporpowderstandardsarenotavailable.分析仪,就选上海禹重实业有限公司,让您满意,欢迎您的来电!如皋LECO230分析仪
Oxygen,Nitrogen,andHydrogeninRefractoryMetalsSummaryOxygenandnitrogenarealloyingelementsintitanium,andarealsoclassifiedasalphastabilizingelementsastheypromotealphaphasealloys.Interstitialoxygenandnitrogenlevelscanbeusedtoregulatethetensilestrengthofthematerial,butduetoitshighsolubilitycancauseunwantedsurfaceembrittlement.Thisphenomenoncanbeleveraged,however,undercontrolledprocessingtocreatesurfacefilmsthatincreasesurfacehardnessandwearproperties.瑞安力可CS844分析仪上海禹重实业有限公司致力于提供分析仪,有想法的不要错过哦!
SamplePreparationSamplingandsamplepreparationisanimportantissuebecausetraditionalmethodsusedtoobtainsamplesforoxygenandnitrogendeterminationaredifferentfromthoserecommendedforhydrogen,especiallywhensamplingmoltenmetal.Themaindifferenceinsteelsamplingproceduresforoxygen/nitrogenandhydrogenisduetothemobilityofhydrogen.Specialprecautionsmustbeusedwhensamplingforhydrogen.Frommoltensteelandiron,asamplemustbequicklyquenchedincoldwaterandchilledinarefrigerantsuchasliquefiednitrogenoramixtureofacetoneandsolidcarbondioxideinordertoreducelossesofhydrogenfromdiffusion.Lossesofoxygenandnitrogenfromdiffusionarenotaproblem.Asamplethatistakenforhydrogenandchilledinarefrigerantcanalsobeusedforoxygenandnitrogendetermination.However,asamplethatistypicallytakenforoxygenand/ornitrogendeterminationisnotsuitableforhydrogendeterminationduetohydrogenloss(diffusion).Surfacecontaminationmustberemovedbyfilingorlightgrinding,usingcarenottooverheatthesample.
InstrumentHighlightsandFeaturesOptionalFeaturesOptionalboom-mountedtouch-screeninterfacepackage(M)promotesanergonomicworkspaceOptionalPerformancePackage(P)addsathree-stagecarriergaspurificationsystem,andadual-loopgasdosemoduleOptionalDualCoolingPackage(D)addsanintegratedliquid-to-airradiatorwithdualcoolingfans.ThisDCoptiongivestheuserthechoiceofliquid-to-liquidcooling,liquid-to-aircooling,oracombinationofbothOptionalintegratedautocleaner(H)automaticallycleanstheupperelectrodeandlowerelectrodetipOptional20-sampleshuttleloaderavailable上海禹重实业有限公司是一家专业提供分析仪的公司,有想法的可以来电咨询!
Procedure–Powder/ChipSamplesInstrumentcalibration/driftcorrection.Addapproximately0.05gof***GraphitePowdertoa***GraphiteCrucible.Firmlyplacethecrucibleonthelowerelectrodetiporappropriateautoloaderposition.PresstheAnalyzebuttonontheinstrumentscreen,thelowerelectrodewillcloseandtheanalysissequencewillstartandendautomatically.Repeatsteps3bthrough3iaminimumofthreetimesforeachcalibration/driftstandardused.分析仪,就选上海禹重实业有限公司,用户的信赖之选,有想法可以来我司咨询!建德分析仪价格
上海禹重实业有限公司是一家专业提供分析仪的公司,欢迎您的来电!如皋LECO230分析仪
氧氮氢分析仪的原理:分析样品在惰性气流存在下于石墨坩埚中加热熔融,其中脉冲炉温度可自由设定,并通过一个非接触式的光学温度传感器进行实时监控,用于实现样品的完全分解,反应所生成的COH2和N2被带入到具有高稳定性和灵敏度的检测系统进行检测。对于CO的检测采用的是非 色散性红外检测器,对于N2和H2的检测则采用热导检测器。氧氮氢分析仪的特点:快速准确分析,自动化操作;精密气体校准;CO红外检测器,高分辨率和重现性的N、H热导池检测器;同一台仪器实现熔融提取和热提取;热提取分析时间可调;可自由选择温度高达2500°C;光学温度计温度测定和控制;所有检测器自动调零/自动水平控制(ALC);数据评估的自动优化选择范围;炉自动清洁和坩埚自动进样(可选);外设电脑进行操作和控制;样品信息保存;所有样品数据可追踪查询;通过FTP或本地局域网进行数据传输;ON,H分析轻松切换。如皋LECO230分析仪
上海禹重实业有限公司发展规模团队不断壮大,现有一支专业技术团队,各种专业设备齐全。致力于创造***的产品与服务,以诚信、敬业、进取为宗旨,以建赛默飞世尔产品为目标,努力打造成为同行业中具有影响力的企业。公司不仅*提供专业的从事仪器科技、医疗科技、检测科技领域内的技术咨询、技术服务,仪器仪表的修理,仪器仪表、实验室设备、机械设备及配件、机电设备及配件、电子产品、化工产品及原料(除危险化学品、监控化学品、烟花爆竹、民用易爆物品、易制毒化学品)、第二类医疗器械的销售,机械设备租赁,电子商务,货物进出口,技术进出口。,同时还建立了完善的售后服务体系,为客户提供良好的产品和服务。禹重科技始终以质量为发展,把顾客的满意作为公司发展的动力,致力于为顾客带来***的光谱仪,色谱仪,质谱仪,样品前处理。
Procedure–Powder/ChipSamplesInstrumentcalibration/...
【详情】Procedure-SolidSamplesInstrumentcalibration/driftc
【详情】Procedure–Powder/ChipSamplesDeterminetheinstrument...
【详情】氧氮氢分析仪的常见故障及解决方法供电正常、通讯正常,点击确认键后分析仪不工作。这是没有水流,炉子温度...
【详情】Instrumentcalibration/driftcorrectionf.Cleantheupp
【详情】Procedure–Powder/ChipSamplesDeterminetheinstrument...
【详情】SamplePreparationTypically,titaniumandzirconiumsam
【详情】InstrumentHighlightsandFeaturesOptionalFeaturesOpt
【详情】